The influence of the tape-core layer number of fluxgate sensor to the demagnetization factor

Closed

Yulkifli, Mitra Djamal, Khairurrijal, Deddy Kurniadi, Pavel Ripka

2009 International Conference on Instrumentation, Communication, Information Technology, and Biomedical Engineering 2009, ICICI-BME 2009 Conference paper Cited by 1

Abstract

This paper explains the influence of the tape-core layer number to the demagnetization factor of a fluxgate sensor. The demagnetization factor was calculated based on the physical dimension, the self-inductance of coil without inserting the core (Lno-core) and by inserting the core (L core) of the sensor. The calculated demagnetization factor to pick-up coil configurations of 2x80 are proportional, 0.51, 0.82, 1.15, and 1.40 x10-3 whereas the one to pick-up coil configurations of 2x20 are 1.02, 1.58, 2.23, and 2.78x10-3, each of which uses the tape-core layer number 1,2, 3, and 4 respectively.

Affiliations

Electronic and Instrumentation Research Group, Faculty of Mathematics and Natural Sciences, Universitas Negeri Padang, 25131, Jl. Prof . Dr. Hamka Padang, Indonesia; Theoretical High Energy Physics and Instrumentation Research Group, Faculty of Mathematics and Natural Sciences, Indonesia; Instrumentation and Control Research Group, Faculty of Industrial Engineering, Institut Teknologi Bandung, Bandung, 40132, Jl. Ganesa 10, Indonesia; Czech Technical University in Prague, Faculty of Electrical Engineering Technicka 2, CZ-16627 Praha 6, Czech Republic